OPTIFLUX 4300 Electromagnetic Flowmeter DN100

Part number OPTIFLUX 4300 C DN100 PN16

Magnetic flowmeter for chemical and process industries, DN2.5–3000, ±0.2 % of rate, PFA/PTFE/ETFE liners, IFC 300 converter with diagnostics, SIL2.

  • CE
  • ATEX
  • IECEx
  • SIL2
  • HART 7
KROHNE OPTIFLUX 4300 Electromagnetic Flowmeter DN100 (OPTIFLUX 4300 C DN100 PN16) — product card

Overview

The OPTIFLUX 4300 pairs KROHNE's OPTIFLUX 4000 sensor with the IFC 300 signal converter — the combination used where process conditions are demanding: aggressive chemicals, high temperatures, slurries and pulsating flow. Accuracy is ±0.2 % of measured value (±0.15 % optional) and the converter provides extended diagnostics: electrode and liner condition, conductivity, linearity and process-noise checks that satisfy verification requirements without removing the meter. Liners in PFA, PTFE, ETFE and ceramic, with electrodes in Hastelloy, tantalum, platinum or titanium, cover nearly any conductive fluid. The DN100 PN16 example is a compact-converter version; remote and Ex d variants are available.

Key features

  • Accuracy ±0.2 % of rate (±0.15 % optional), sizes DN2.5 to DN3000
  • IFC 300 converter with full diagnostics: electrode, liner, conductivity, linearity, noise
  • Liners PFA, PTFE, ETFE, ceramic; electrodes Hastelloy C, tantalum, platinum, titanium
  • Virtual reference option removes the need for grounding rings in plastic pipes
  • 4–20 mA HART 7, pulse, status; FF, PROFIBUS PA/DP, Modbus options; SIL2

Typical applications

  • Acids, caustics and solvents in chemical plants
  • Hot and corrosive liquids in pulp and paper
  • Dosing and process water in power plants
  • Pharmaceutical and food process lines

Technical specifications — OPTIFLUX 4300 C DN100 PN16

Measurement
Measuring principleElectromagnetic
SizesDN2.5–DN3000 (sensor OPTIFLUX 4000)
Accuracy±0.2 % of rate (±0.15 % option)
Minimum conductivity1 µS/cm (20 µS/cm in Ex versions)
Output
ConverterIFC 300 compact or remote
Signal4–20 mA HART 7, pulse, status; FF, PROFIBUS, Modbus options
Power100–230 V AC or 24 V DC
Process
Process temperature-40…+180 °C (PFA/PTFE)
Process pressureup to PN40 / Class 300
Process connectionFlanges EN, ASME, JIS
Liner / electrodesPFA, PTFE, ETFE, ceramic / Hastelloy C, Ta, Pt, Ti
Environment
Ambient temperature-40…+65 °C
EnclosureIP66/67 (IP68 remote sensor)

Specifications are summarised from the manufacturer's documentation for selection purposes. Always confirm against the current datasheet before design-in; we send the datasheet and the exact ordering code with every quotation.

Related part numbers and alternatives

Part numberRelationship
OPTIFLUX 2300Water and wastewater version with hard-rubber or PP linerQuote
OPTIFLUX 4400Same sensor with the IFC 400 converter for SIL2/3 and extended I/OQuote
WATERFLUX 3300Battery-powered water meter for district meteringQuote

Not sure which variant you need? Send us the nameplate photo or the old part number and we will identify the current equivalent.

Supply, documentation and lead time

What you receive

  • Genuine KROHNE product in original packaging
  • Commercial invoice and packing list; Certificate of Conformance on request
  • Datasheet, declaration of conformity and country of origin as issued by the manufacturer
  • Manufacturer warranty, period stated on the quotation

How we quote

  • Reply within one business day with price, lead time and stock position
  • Alternatives proposed when they improve price or delivery
  • Incoterms of your choice: EXW Hai Phong, FOB/FCA, CIF/DAP to your site
  • Consolidated shipments for multi-line orders; export documentation for buyers outside Vietnam

Indicative HS code 9026.10 — final classification is confirmed on the commercial invoice.

Frequently asked questions

What is the difference between OPTIFLUX 4300 and OPTIFLUX 2300?

Both use the IFC 300 converter. OPTIFLUX 2000 sensors are designed for water and wastewater with hard-rubber or polypropylene liners; OPTIFLUX 4000 sensors carry PFA/PTFE/ceramic liners and exotic electrodes for chemical and high-temperature duty.

Can the meter be verified in place?

Yes. The IFC 300 runs internal diagnostics on the electrodes, liner and electronics and generates a verification report; the optional OPTICHECK tool provides a documented on-site verification without process interruption.

Is the OPTIFLUX 4300 available from stock, and what is the lead time?

Common PFA/Hastelloy sizes DN25–DN200 are typically 4–8 weeks; ceramic liners and large sizes longer. We confirm with the quotation.

Send us a part number, a BOM or a drawing.

Our engineers reply within one business day with availability, lead time and alternatives where they save you cost or time.

ZaloCallEmail