Emerson (Rosemount, Micro Motion) · Flow Meters
Micro Motion F-Series F050 Coriolis Flowmeter
Part number F050S319C2BAEZZZZ
Compact drainable Coriolis mass flowmeter, 1/2 in / DN15, ±0.10 % liquid mass flow accuracy, density output, 4–20 mA HART, for dosing, blending and custody transfer.
- CE
- ATEX
- IECEx
- SIL2
- HART

Overview
Micro Motion F-Series meters are compact, self-draining Coriolis flowmeters for installations where space is tight or hygiene matters. The F050 covers nominal 1/2-inch lines with liquid mass flow accuracy of ±0.10 % of rate and density accuracy of ±0.002 g/cm³, measuring mass, volume, density and temperature in one device with no straight-run requirement. Combined with a 2700 or 5700 transmitter it provides batch control, concentration measurement and Smart Meter Verification for in-situ health checks. The example code is a 316L sensor with integral transmitter and ATEX approval; we configure sensor size, wetted material, transmitter and I/O against your fluid and flow range.
Key features
- Mass flow ±0.10 % of rate (liquids), density ±0.002 g/cm³, temperature in the same meter
- Compact, self-draining design for hygienic and skid-mounted installations
- No straight-run requirements, immune to flow profile and conductivity
- Smart Meter Verification: in-line health check without process interruption
- Integral or remote 2700/5700 transmitter: 4–20 mA HART, pulse, Modbus, FF, PROFIBUS; SIL2
Typical applications
- Chemical dosing and additive injection
- Batch filling and blending in food and beverage plants
- Fuel and solvent custody transfer
- Concentration and Brix measurement via density
Technical specifications — F050S319C2BAEZZZZ
| Measurement | |
|---|---|
| Measuring principle | Coriolis mass flow |
| Nominal size | 1/2 in / DN15 (F-Series DN15–DN100) |
| Liquid mass flow accuracy | ±0.10 % of rate |
| Density accuracy | ±0.002 g/cm³ |
| Nominal flow | up to ~2,700 kg/h (F050) |
| Output | |
| Transmitter | 2700 or 5700, integral or remote |
| Signal | 4–20 mA HART, frequency/pulse, discrete; Modbus, FF, PROFIBUS options |
| Power | 18–100 V DC or 85–265 V AC (transmitter) |
| Process | |
| Process temperature | -40…+204 °C (-40…+150 °C with integral transmitter) |
| Process connection | Flanges ANSI/DIN, Tri-Clamp, threaded |
| Wetted material | 316L SST (nickel alloy option) |
| Environment | |
| Ambient temperature | -40…+60 °C |
| Enclosure | IP66/67 |
Specifications are summarised from the manufacturer's documentation for selection purposes. Always confirm against the current datasheet before design-in; we send the datasheet and the exact ordering code with every quotation.
Related part numbers and alternatives
| Part number | Relationship | |
|---|---|---|
F025 | Smaller 1/4-inch F-Series sensor for low flows | Quote |
CMF050 | ELITE CMF050 — higher accuracy ±0.05 % and wider turndown | Quote |
R050 | R-Series — economy Coriolis for utility and non-custody applications | Quote |
Not sure which variant you need? Send us the nameplate photo or the old part number and we will identify the current equivalent.
Supply, documentation and lead time
What you receive
- Genuine Emerson (Rosemount, Micro Motion) product in original packaging
- Commercial invoice and packing list; Certificate of Conformance on request
- Datasheet, declaration of conformity and country of origin as issued by the manufacturer
- Manufacturer warranty, period stated on the quotation
How we quote
- Reply within one business day with price, lead time and stock position
- Alternatives proposed when they improve price or delivery
- Incoterms of your choice: EXW Hai Phong, FOB/FCA, CIF/DAP to your site
- Consolidated shipments for multi-line orders; export documentation for buyers outside Vietnam
Indicative HS code 9026.10 — final classification is confirmed on the commercial invoice.
Frequently asked questions
Should I choose the F-Series or the ELITE CMF series?
ELITE offers ±0.05 % accuracy and the best low-flow performance for custody transfer and demanding density applications. The F-Series gives ±0.10 % in a compact, drainable body at lower cost, which is adequate for most dosing and batching loops. We quote by required accuracy and installation space.
Does the F050 need straight pipe upstream and downstream?
No. Coriolis measurement is independent of flow profile, so the meter can be installed directly after elbows, valves or pumps — one of its main advantages over magnetic and vortex meters.
Is the Micro Motion F050 available from stock, and what is the lead time?
Typical factory lead time is 4–8 weeks depending on transmitter and approvals. We confirm with the quotation.