FCS-G1/2A4-AP8X-H1141 Flow Monitor (Calorimetric)
Part number FCS-G1/2A4-AP8X-H1141
Calorimetric immersion flow monitor for liquids, G1/2 stainless probe, 1–150 cm/s detection, PNP output with teach-in, M12, for cooling-water and pump dry-run monitoring.
- CE
- IP67
- PNP
- Immersion

Overview
The Turck FCS-G1/2A4-AP8X-H1141 is a compact calorimetric flow monitor: a stainless-steel probe with a G1/2 thread inserted into the pipe detects whether liquid is flowing, switching a PNP output when flow drops below the taught threshold. The sensor has no moving parts, is independent of pipe size and is used mainly for cooling-water monitoring on welding guns, spindles and lasers, and for dry-run protection of pumps. Setup is by teach-in with the potentiometer or keys, and the LED chain shows the flow relative to the switch point. Versions for gases, with 4–20 mA output (FCS-...-LIX) and with integrated temperature measurement are available in the FCS/FCI family.
Key features
- Calorimetric principle, no moving parts, independent of pipe diameter
- Detection range 1–150 cm/s for water; teach-in switch point; LED flow indication
- PNP NO output 400 mA, 19.2–28.8 V DC; M12 connector
- G1/2 stainless probe (316 Ti), 24 mm immersion; medium -20…+80 °C; 100 bar
- IP67 housing; variants with 4–20 mA, temperature output or for gases
Typical applications
- Cooling-water flow monitoring on welding and laser equipment
- Dry-run protection of pumps
- Lubrication and hydraulic circuit monitoring
- Flow/no-flow detection in process lines
Technical specifications — FCS-G1/2A4-AP8X-H1141
| Measurement | |
|---|---|
| Principle | Calorimetric |
| Detection range | 1–150 cm/s (water) |
| Medium | Liquids (gas version available) |
| Response time | 2–10 s typical |
| Temperature gradient | ≤ 0.4 K/min |
| Output | |
| Output | PNP NO, 400 mA |
| Adjustment | Teach-in / potentiometer |
| Indication | LED chain, flow relative to set point |
| Power | 19.2–28.8 V DC |
| Process | |
| Process connection | G1/2 |
| Probe | 316 Ti stainless, 24 mm |
| Medium temperature | -20…+80 °C |
| Pressure | 100 bar |
| Environment | |
| Ambient temperature | -20…+70 °C |
| Protection | IP67 |
| Connection | M12 × 1, 4-pin |
Specifications are summarised from the manufacturer's documentation for selection purposes. Always confirm against the current datasheet before design-in; we send the datasheet and the exact ordering code with every quotation.
Related part numbers and alternatives
| Part number | Relationship | |
|---|---|---|
FCS-G1/2A4-LIX-H1141 | Version with 4–20 mA analog output | Quote |
FCS-G1/2A4-AP8X-H1141/D100 | Version for gases | Quote |
SM6000 | ifm magnetic-inductive meter when flow rate is needed | Quote |
Not sure which variant you need? Send us the nameplate photo or the old part number and we will identify the current equivalent.
Supply, documentation and lead time
What you receive
- Genuine Turck product in original packaging
- Commercial invoice and packing list; Certificate of Conformance on request
- Datasheet, declaration of conformity and country of origin as issued by the manufacturer
- Manufacturer warranty, period stated on the quotation
How we quote
- Reply within one business day with price, lead time and stock position
- Alternatives proposed when they improve price or delivery
- Incoterms of your choice: EXW Hai Phong, FOB/FCA, CIF/DAP to your site
- Consolidated shipments for multi-line orders; export documentation for buyers outside Vietnam
Indicative HS code 9026.10 — final classification is confirmed on the commercial invoice.
Frequently asked questions
Does the FCS measure the flow rate?
The standard AP8X version is a flow monitor: it switches above or below a taught flow velocity. For an analog flow signal choose the LIX version, or a magnetic-inductive meter for accurate volume flow.
How long does it take to react when flow stops?
Calorimetric sensors respond within a few seconds; the exact time depends on the medium and the difference between set point and actual flow. For pump protection this is normally sufficient.
Is the FCS-G1/2A4-AP8X-H1141 available from stock, and what is the lead time?
Typically 1–2 weeks from Turck regional stock. We confirm with the quotation.