IL-300 CMOS Laser Displacement Sensor Head
Part number IL-300 + IL-1000 amplifier
Analog laser displacement sensor, 300 mm reference distance, ±140 mm range, 30 µm repeatability, used with IL-1000 amplifier for 4–20 mA / ±5 V output, thickness and height measurement.
- CE
- IP67
- Class 2 laser
- ±0.25 %

Overview
The Keyence IL series is a CMOS multi-function analog laser sensor for measuring height, thickness, position and flatness with a simple two-piece design: a sensor head and a DIN-rail amplifier. The IL-300 head has a reference distance of 300 mm and a measuring range of 160–450 mm with 30 µm repeatability; its CMOS array and "HSE" processing give stable results on metal, black rubber and glossy surfaces. The IL-1000 amplifier provides a ±5 V or 4–20 mA analog output, two comparator outputs, and calculation modes such as thickness (two heads) and step. Amplifiers can be linked for multi-head measurement and connected to a PLC via the DL-series communication units (EtherNet/IP, PROFINET, RS-232C).
Key features
- Reference distance 300 mm, range 160–450 mm, repeatability 30 µm, linearity ±0.25 % FS
- CMOS with HSE processing for stable measurement on metal, black and glossy targets
- IL-1000 amplifier: ±5 V and 4–20 mA output, 2 comparator outputs, calculation (thickness, step)
- Sampling 0.33 ms; IP67 head with Class 2 visible laser
- Multi-head linking and DL-EP1/DL-PN1 communication units for EtherNet/IP and PROFINET
Typical applications
- Thickness measurement of sheets and boards (two heads)
- Height and seating check of assembled parts
- Warpage and flatness inspection
- Position feedback for tension and gap control
Technical specifications — IL-300 + IL-1000 amplifier
| Sensing | |
|---|---|
| Reference distance | 300 mm |
| Measuring range | 160–450 mm |
| Repeatability | 30 µm |
| Linearity | ±0.25 % of FS |
| Light source | Red laser 655 nm, Class 2 |
| Sampling | 0.33 ms (1 ms, 2 ms, 5 ms selectable) |
| Output | |
| Amplifier | IL-1000 (DIN rail), IL-1500 (dual output) |
| Analog output | ±5 V or 4–20 mA (selectable) |
| Control outputs | 2 comparator outputs NPN or PNP |
| Power | 10–30 V DC |
| Construction | |
| Head housing | Aluminium die-cast |
| Cable | Head to amplifier 2 m (extension to 10 m) |
| Communication | DL-EP1, DL-PN1, DL-RS1A units |
| Environment | |
| Ambient temperature | -10…+50 °C |
| Protection | IP67 (head) |
| Ambient light | 5,000 lux |
Specifications are summarised from the manufacturer's documentation for selection purposes. Always confirm against the current datasheet before design-in; we send the datasheet and the exact ordering code with every quotation.
Related part numbers and alternatives
| Part number | Relationship | |
|---|---|---|
IL-100 | Shorter 100 mm reference distance head for higher precision | Quote |
IL-600 | 600 mm reference head for long range | Quote |
LK-G5000 | High-precision laser displacement sensor for sub-micron measurement | Quote |
Not sure which variant you need? Send us the nameplate photo or the old part number and we will identify the current equivalent.
Supply, documentation and lead time
What you receive
- Genuine Keyence product in original packaging
- Commercial invoice and packing list; Certificate of Conformance on request
- Datasheet, declaration of conformity and country of origin as issued by the manufacturer
- Manufacturer warranty, period stated on the quotation
How we quote
- Reply within one business day with price, lead time and stock position
- Alternatives proposed when they improve price or delivery
- Incoterms of your choice: EXW Hai Phong, FOB/FCA, CIF/DAP to your site
- Consolidated shipments for multi-line orders; export documentation for buyers outside Vietnam
Indicative HS code 9031.49 — final classification is confirmed on the commercial invoice.
Frequently asked questions
Do I need one amplifier per head?
Yes. Each IL head connects to its own IL-1000/IL-1500 amplifier; amplifiers are linked side by side for calculations such as thickness (head A + head B).
Can the measurement go directly to a PLC?
With a DL-EP1 (EtherNet/IP) or DL-PN1 (PROFINET) communication unit the measured values and settings are read over the network; otherwise the 4–20 mA output feeds an analog input card.
Is the IL-300 available, and what is the lead time?
Typically 2–3 weeks for head and amplifier through authorized channels. We confirm with the quotation.