Industry
Logistics & Material Handling: automation and instrumentation supply
Warehouses and sortation centers depend on thousands of sensors and hundreds of drives working together. HOANTRANTDH supplies photoelectric and distance sensors, machine drives, safety light curtains and the networking that ties conveyor zones together.
- Background-suppression photoelectric sensors with IO-Link
- Compact machine drives for conveyor motors
- Safety light curtains for access points
- Unmanaged and managed switches for zone controllers
Products commonly specified in logistics & material handling
SiemensSIMATIC S7-1200 CPU 1214C DC/DC/DC
6ES7214-1AG40-0XB0Compact PLC with 14 DI / 10 DO / 2 AI on board, 100 KB work memory and integrated PROFINET.SiemensLOGO! 8 12/24RCE Logic Module6ED1052-1MD08-0BA1Logic module with 8 digital inputs (4 usable as analog), 4 relay outputs, Ethernet and integrated web server.Schneider ElectricModicon M221 TM221CE16R ControllerTM221CE16RCompact PLC with 9 inputs, 7 relay outputs, 2 analog inputs, Ethernet and serial line, 100–240 V AC supply.Rockwell AutomationMicro850 24-Point Controller 2080-LC50-24QBB2080-LC50-24QBBAllen-Bradley compact PLC with 14 DI / 10 DO (24 V DC), embedded EtherNet/IP, four 100 kHz counters and three plug-in slots.Schneider ElectricAltivar Machine ATV320 1.5 kWATV320U15N4CCompact machine drive, 1.5 kW, 3-phase 380–500 V, with STO (SIL2/PLd), Modbus and CANopen on board.Rockwell AutomationPowerFlex 525 AC Drive 4 kW25B-D010N104Compact VFD, 4 kW / 5 HP, 380–480 V 3-phase, embedded EtherNet/IP, Safe Torque Off, V/Hz, SVC and closed-loop vector control.SICKdeTec4 Core Safety Light CurtainC4C-SA18030A10000Type 4 safety light curtain, 300 mm protective height, 14 mm resolution (finger protection), sender unit of the deTec4 Core series.Schneider ElectricPreventa XPSU Safety Relay ModuleXPSUAF13APUniversal safety relay for e-stop and guard monitoring up to Cat. 4 / PL e / SIL 3, 3 NO safety contacts + 1 NC, 24 V AC/DC to 240 V AC supply.ABBCP-E 24/10.0 Power Supply 24 V / 10 A1SVR427035R0000Economy DIN-rail power supply, 24 V DC / 10 A, 90–264 V AC input, full load up to 50 °C, DC-OK contact.OmronE2E Inductive Proximity Sensor M30E2E-X10D1-NShielded M30 inductive sensor, 10 mm sensing distance, DC 2-wire NO output, pre-wired, IP67 brass housing.SICKW16 WTB16P Photoelectric Proximity SensorWTB16P-24162120A00Background-suppression photoelectric sensor, 40–950 mm range, PNP, IO-Link v1.1, BluePilot alignment, M12 connector.Pepperl+FuchsUB800 Ultrasonic Sensor M18UB800-18GM40-E5-V1Ultrasonic proximity sensor, 50–800 mm sensing range, independent of colour and transparency, PNP output, M18 housing, M12 connector.SICKDT35 Mid-Range Distance SensorDT35-B15251Laser time-of-flight distance sensor, 50 mm to 12 m on natural surfaces, ±1 mm repeatability, 4–20 mA analog, switching and IO-Link outputs.MoxaEDS-408A Managed Ethernet SwitchEDS-408A8-port entry-level managed Ethernet switch with Turbo Ring and Turbo Chain redundancy (< 20 ms), dual power input, DIN rail.Phoenix ContactFL SWITCH 2008 Unmanaged Switch28910308-port unmanaged industrial Ethernet switch, 10/100 Mbit/s, slim metal housing, 24 V DC, -10…+60 °C.MoxaEDS-G4012 Managed Gigabit SwitchEDS-G4012-8P2S-LV12-port full-Gigabit managed switch with 8 × PoE+ and 2 × SFP, Turbo Ring/MRP redundancy, IEC 62443-4-2 security, -40…+75 °C.MoxaUC-2112-LX Arm Edge ComputerUC-2112-LXCompact Arm-based edge computer with Moxa Industrial Linux, 2 × LAN, 2 × serial, microSD, fanless -40…+70 °C, for data acquisition and protocol conversion.MoxaOnCell G3150A-LTE Industrial Cellular GatewayOnCell G3150A-LTE-EUIndustrial LTE Cat 4 gateway with 1 × Ethernet and 1 × serial, dual SIM, IPsec/OpenVPN, GuaranLink recovery, -30…+70 °C.These are the products we document on this site. We source the full manufacturer catalogue — send any part number for a quote.
Engineering guides
- Safety Relays vs Safety PLC: Where Is the Crossover Point?PLC · 6 min read
- IEC 61131-3 Languages: Ladder, ST, FBD — Which to Use WhenPLC · 7 min read
- Segmenting OT Networks: VLANs, DMZ and IEC 62443 Zones in PracticeNetworking · 8 min read