WIKA · Temperature Instruments
TR10-C Resistance Thermometer with Thermowell
Part number TR10-C Pt100 4-wire Class A, 1/2 NPT, TW10 thermowell
Industrial Pt100 RTD assembly with replaceable measuring insert, connection head and screw-in thermowell, class A, -200…+600 °C, 4–20 mA head transmitter optional.
- IEC 60751
- ATEX
- IECEx
- Class A

Overview
The WIKA TR10-C is the classic process RTD assembly: a connection head (BSZ, BSZ-H or BSS in aluminium or stainless), a replaceable TR10-A measuring insert with a Pt100 element, a neck tube and a threaded thermowell. The insert can be exchanged without opening the process, and the head accepts a T32 or T15 head-mounted transmitter so the assembly delivers 4–20 mA HART directly. Elements are class A or B per IEC 60751 in 3- or 4-wire configuration, single or duplex, with measuring ranges from -200 to +600 °C. Thermowells in 316 or 316L in screw-in, weld-in or flanged designs are selected to the process pressure and velocity; we calculate the wake-frequency check on request. The example is a 1/2 NPT screw-in assembly with TW10 thermowell.
Key features
- Replaceable TR10-A measuring insert, spring-loaded, exchangeable under process
- Pt100 class A or B, 3- or 4-wire, single or duplex; -200…+600 °C
- Connection heads BSZ/BSZ-H/BSS in aluminium or 316 SST, IP65/IP66
- Optional T32 (HART) or T15 head transmitter for 4–20 mA output
- Thermowells TW10/TW15/TW35 in 316/316L; ATEX/IECEx Ex i/Ex d versions
Typical applications
- Process temperature in pipelines and vessels
- Boiler and heat-exchanger temperature
- Utility and HVAC monitoring
- Replacement of obsolete RTD assemblies from any manufacturer
Technical specifications — TR10-C Pt100 4-wire Class A, 1/2 NPT, TW10 thermowell
| Measurement | |
|---|---|
| Sensor | Pt100 (Pt1000 option), 1 × or 2 × element |
| Class | A or B per IEC 60751; 3- or 4-wire |
| Range | -200…+600 °C (wire-wound), -50…+250 °C (thin-film) |
| Insert diameter | 6 or 8 mm, spring-loaded |
| Output | |
| Terminal | Ceramic terminal block in head |
| Transmitter option | T32 (HART, 4–20 mA), T15 (4–20 mA), T53 (FF/PA) |
| Process | |
| Thermowell | TW10 screw-in, TW15 weld-in, TW35 flanged; 316/316L |
| Process connection | 1/2 NPT, G1/2, G3/4, flanges |
| Neck tube | 12 mm, lengths per order |
| Environment | |
| Head protection | IP65 / IP66 |
| Approvals | ATEX, IECEx, FM, CSA (Ex i, Ex d, Ex e) |
Specifications are summarised from the manufacturer's documentation for selection purposes. Always confirm against the current datasheet before design-in; we send the datasheet and the exact ordering code with every quotation.
Related part numbers and alternatives
| Part number | Relationship | |
|---|---|---|
TR10-B | Version with insert and head but without thermowell | Quote |
TC10-C | Thermocouple assembly in the same mechanical design | Quote |
iTHERM TM411 | Endress+Hauser hygienic alternative with quick-release neck | Quote |
Not sure which variant you need? Send us the nameplate photo or the old part number and we will identify the current equivalent.
Supply, documentation and lead time
What you receive
- Genuine WIKA product in original packaging
- Commercial invoice and packing list; Certificate of Conformance on request
- Datasheet, declaration of conformity and country of origin as issued by the manufacturer
- Manufacturer warranty, period stated on the quotation
How we quote
- Reply within one business day with price, lead time and stock position
- Alternatives proposed when they improve price or delivery
- Incoterms of your choice: EXW Hai Phong, FOB/FCA, CIF/DAP to your site
- Consolidated shipments for multi-line orders; export documentation for buyers outside Vietnam
Indicative HS code 9025.19 — final classification is confirmed on the commercial invoice.
Frequently asked questions
Do you supply the thermowell with the thermometer?
Yes. We quote the assembly complete — head, insert, neck tube and thermowell — matched in length and connection, and provide the wake-frequency (ASME PTC 19.3) calculation for high-velocity lines.
Can I replace the insert without shutting down the process?
Yes. With a thermowell installed, the spring-loaded TR10-A insert is removed through the head while the thermowell keeps the process sealed.
Is the TR10-C available from stock, and what is the lead time?
Standard lengths with Pt100 class A and TW10 thermowell are typically 2–3 weeks; Ex d or flanged versions 4–6 weeks. We confirm with the quotation.